Annexes to COM(2002)581 - Quality of bathing water - Main contents
Please note
This page contains a limited version of this dossier in the EU Monitor.
dossier | COM(2002)581 - Quality of bathing water. |
---|---|
document | COM(2002)581 |
date | February 15, 2006 |
For inland waters
A | B | C | D | E | |
Parameter | Excellent quality | Good quality | Sufficient | Reference methods of analysis | |
1 | Intestinal enterococci (cfu/100 ml) | 200 (1) | 400 (1) | 330 (2) | ISO 7899-1 or ISO 7899-2 |
2 | Escherichia coli (cfu/100 ml) | 500 (1) | 1 000 (1) | 900 (2) | ISO 9308-3 or ISO 9308-1 |
For coastal waters and transitional waters
A | B | C | D | E | |
Parameter | Excellent quality | Good quality | Sufficient | Reference methods of analysis | |
1 | Intestinal enterococci (cfu/100 ml) | 100 (3) | 200 (3) | 185 (4) | ISO 7899-1 or ISO 7899-2 |
2 | Escherichia coli (cfu/100 ml) | 250 (3) | 500 (3) | 500 (4) | ISO 9308-3 or ISO 9308-1 |
(1) Based upon a 95‐percentile evaluation. See Annex II.
(2) Based upon a 90‐percentile evaluation. See Annex II.
(3) Based upon a 95‐percentile evaluation. See Annex II.
(4) Based upon a 90‐percentile evaluation. See Annex II.
ANNEX II
Bathing water assessment and classification
1. Poor quality
Bathing waters are to be classified as ‘poor’ if, in the set of bathing water quality data for the last assessment period (1), the percentile values (2) for microbiological enumerations are worse (3) than the ‘sufficient’ values set out in Annex I, column D.
2. Sufficient quality
Bathing waters are to be classified as ‘sufficient’:
1. | if, in the set of bathing water quality data for the last assessment period, the percentile values for microbiological enumerations are equal to or better (4) than the ‘sufficient’ values set out in Annex I, column D; and |
2. | if the bathing water is subject to short-term pollution, on condition that:
|
3. Good quality
Bathing waters are to be classified as ‘good’:
1. | if, in the set of bathing water quality data for the last assessment period, the percentile values for microbiological enumerations are equal to or better (4) than the ‘good quality’ values set out in Annex I, column C; and |
2. | if the bathing water is subject to short-term pollution, on condition that:
|
4. Excellent quality
Bathing waters are to be classified as ‘excellent’:
1. | if, in the set of bathing water quality data for the last assessment period, the percentile values for microbiological enumerations are equal to or better than the ‘excellent quality’ values set out in Annex I, column B; and |
2. | if the bathing water is subject to short-term pollution, on condition that:
|
NOTES
(1) ‘Last assessment period’ means the last four bathing seasons or, when applicable, the period specified in Article 4(2) or (4).
(2) Based upon percentile evaluation of the log10 normal probability density function of microbiological data acquired from the particular bathing water, the percentile value is derived as follows:
(i) | Take the log10 value of all bacterial enumerations in the data sequence to be evaluated. (If a zero value is obtained, take the log10 value of the minimum detection limit of the analytical method used instead.) |
(ii) | Calculate the arithmetic mean of the log10 values (μ). |
(iii) | Calculate the standard deviation of the log10 values (σ). |
The upper 90‐percentile point of the data probability density function is derived from the following equation: upper 90‐percentile = antilog (μ + 1,282 σ).
The upper 95‐percentile point of the data probability density function is derived from the following equation: upper 95‐percentile = antilog (μ + 1,65 σ).
(3) ‘Worse’ means with higher concentration values expressed in cfu/100 ml.
(4) ‘Better’ means with lower concentration values expressed in cfu/100 ml.
ANNEX III
The bathing water profile
1. | The bathing water profile referred to in Article 6 is to consist of:
|
2. | In the case of bathing waters classified as ‘good’, ‘sufficient’ or ‘poor’, the bathing water profile is to be reviewed regularly to assess whether any of the aspects listed in paragraph 1 have changed. If necessary, it is to be updated. The frequency and scope of reviews is to be determined on the basis of the nature and severity of the pollution. However, they are to comply with at least the provisions and to take place with at least the frequency specified in the following table.
In the case of bathing waters previously classified as ‘excellent’, the bathing water profiles need be reviewed and, if necessary, updated only if the classification changes to ‘good’, ‘sufficient’ or ‘poor’. The review is to cover all aspects mentioned in paragraph 1. |
3. | In the event of significant construction works or significant changes in the infrastructure in or in the vicinity of the bathing water, the bathing water profile is to be updated before the start of the next bathing season. |
4. | The information referred to in paragraph 1(a) and (b) is to be provided on a detailed map whenever practicable. |
5. | Other relevant information may be attached or included if the competent authority considers it appropriate. |
ANNEX IV
Bathing water monitoring
1. | One sample is to be taken shortly before the start of each bathing season. Taking account of this extra sample and subject to paragraph 2, no fewer than four samples are to be taken and analysed per bathing season. |
2. | However, only three samples need be taken and analysed per bathing season in the case of a bathing water that either:
|
3. | Sampling dates are to be distributed throughout the bathing season, with the interval between sampling dates never exceeding one month. |
4. | In the event of short-term pollution, one additional sample is to be taken to confirm that the incident has ended. This sample is not to be part of the set of bathing water quality data. If necessary to replace a disregarded sample, an additional sample is to be taken seven days after the end of the short-term pollution. |
ANNEX V
Rules on the handling of samples for microbiological analyses
1. Sampling point
Where possible, samples are to be taken 30 centimetres below the water's surface and in water that is at least one metre deep.
2. Sterilisation of sample bottles
Sample bottles are:
— | to undergo sterilisation in an autoclave for at least 15 minutes at 121 oC, or |
— | to undergo dry sterilisation at between 160 oC and 170 oC for at least one hour, or |
— | to be irradiated sample containers obtained directly from manufacturer. |
3. Sampling
The volume of the sampling bottle/container is to depend on the quantity of water needed for each parameter to be tested. The minimum content is generally 250 ml.
Sample containers are to be of transparent and non-coloured material (glass, polyethene or polypropylene).
In order to prevent accidental contamination of the sample, the sampler is to employ an aseptic technique to maintain the sterility of the sample bottles. There is no further need for sterile equipment (such as sterile surgical gloves or tongs or sample pole) if this is done properly.
The sample is to be clearly identified in indelible ink on the sample and on the sampling form.
4. Storage and transport of samples before analysis
Water samples are to be protected at all stages of transport from exposure to light, in particular direct sunlight.
The sample is to be conserved at a temperature of around 4 oC, in a cool box or refrigerator (depending on climate) until arrival at the laboratory. If the transport to the laboratory is likely to take more than four hours, then transport in a refrigerator is required.
The time between sampling and analysis is to be kept as short as possible. It is recommended that samples be analysed on the same working day. If this is not possible for practical reasons, then the samples shall be processed within no more than 24 hours. In the meantime, they shall be stored in the dark and at a temperature of 4 oC ± 3 oC.